Home >> Life Science >> Microscopes & Imaging Systems >> Fluoview® FV1000MPE femtoCARS Add-on
A low-cost high-performance accessory for multimodal in vivo imaging without the need for staining protocols or fluorescent protein expression.

The femtoCARS equipped FV1000MPE provides a label-free lipid imaging capability based on molecular vibrations using the Coherent Anti-Stokes Raman Scattering (CARS) microscopy method. CARS is a non-linear optical method with high chemical selectivity and sensitivity that is improved orders of magnitude relative to conventional Raman detection. In Olympus's design, the CARS imaging mode can be combined with two photon excitation fluorescence (TPEF) and second harmonic generation (SHG) imaging modes as a multimodal femtosecond laser imaging station. The femtoCARS add-on provides an entirely new commercial solution for investigating structures such as the myelin sheath, intracelluar lipid bodies, mechanisms underlying fat storage and membrane organization, as well as tissue and skin reorganization in vivo.

International Dealers

Feature & Benefits:

  • Simultaneous Lipid (CH2), TPEF, and SHG imaging. The lipid filter set is included and TPEF and SHG filter sets are optional.
  • Uses the standard Olympus DeepSee lasers which are specifically tuned to match Olympus’ optical requirements. No additional laser is required.
  • The output of the femtoCARS is pre-set to lipid detection.
  • Standard MPE detection system, up to two forward (transmitted) and four backward (epi) Non-Descanned Detection channels.
  • Standard MPE imaging (by-pass CARS add-on) and single photon imaging are available.
  • The optical delivery system including a laser-safe enclosure is provided and serviced by Olympus America, Inc.
  • The overall footprints for MPE with femtoCARS remain small, but different from regular MPE systems.
  • Upright platforms are standard. For inverted platform, please contact Olympus America, Inc.
  • Acousto-optical modulation (AOM) standard for MPE and manual power adjustment operation for the Stokes’ beam.
  • Dispersion compensation standard for MPE and for efficient Stokes’ beam generation.

    The femtoCARS add-on unit is only available in US and Canada currently.

    Return to FluoView MPE Multiphoton Microscopes Summary Page.







Microscopes Home |  UIS2 Optics |  Microscopy Resource Center |  FluoView Resource Center |  Financial Services |  Contact Olympus

© 2009 Olympus America Inc.  |  November 21, 2009  |  Privacy Statement  |  Terms of Use